loading

A professional manufacturer of measuring & testing equipment.

How does the two-dimensional measuring instrument reduce various errors?

How does the two-dimensional measuring instrument reduce various errors? Published: 2019-10-28 Source: http://www.microaccuracy.com/ Various error conditions have always been an important factor affecting the accuracy of the two-dimensional measuring instrument. As a high-precision measuring instrument, the two-dimensional measuring instrument is used in the process To avoid accuracy errors caused by various factors, how can the two-dimensional measuring instrument reduce various errors? Mechanical errors, optical errors, and operating errors are the most common error factors in the use of a two-dimensional measuring instrument. The two-dimensional measuring instrument can avoid errors as much as possible through the following measures, thereby improving the detection accuracy: Mechanical errors: mainly caused by two In the process of manufacturing and assembling the dimensional measuring instrument, this error can be effectively reduced by improving the quality of manufacturing and assembly. For example: ① When the guide rail device is on the base, it is necessary to ensure a sufficient degree, and the degree of accuracy must be marked by a dial indicator. ②The XY grating ruler needs to be complete without any inclination. ③The X and Y worktables are required to be parallel, which requires the time division of the guide rail device. Optical error: This is caused by the distortion and distortion produced by the imaging optical path and components. When the light passes through each lens, the refraction error and the CCD dot matrix position error occur, so there is nonlinear geometric distortion in the optical system, which causes There are various types of geometric distortion between the target image point and the theoretical image point. The lens and the optical axis of the lens must be adjusted and checked according to the distortion. Operation error: This is the error situation caused by the operation error in the use process. This error situation is more common in manual and semi-automatic measuring equipment. It is generally reflected in the error of taking the point and the error of the Z-axis focal length adjustment. Automatic image measuring instrument can reduce the influence of operation on detection, thereby avoiding human operation error. The above are several common error generation situations of two-dimensional measuring instruments. Improvements from the root cause can effectively reduce the occurrence of errors. In particular, the use of fully automatic measuring equipment will greatly improve the measurement accuracy. At present, Miaoji Technology can provide more High-quality equipment such as automatic two-dimensional measuring instrument, one-button measuring instrument and so on!

GET IN TOUCH WITH Us
recommended articles
200 FAQs WHAT' S NEW APPLICATION
How to keep the hydraulic universal testing machine clean



Hydraulic universal testing machines have very high accuracy requirements.
Connection of hydraulic system of tensile testing machine



The hydraulic system is the power drive mechanism of the tensile testing machine.
Application of electronic universal testing machine in automobile industry



The specific application of the electronic universal testing machine in the automobile manufacturing process: The electronic universal testing machine needs to be used for automobile parts.
Wave soldering workflow



Wave soldering refers to the molten solder (lead-tin alloy), sprayed by electric pump or electromagnetic pump into the solder wave required by the design, can also be formed by injecting nitrogen into the solder pool, so that it is pre-loaded The printed board of the component realizes the soft soldering of the mechanical and electrical connection between the solder end or the pin of the component and the pad of the printed board through the solder wave.
Protection of frequency converter of hydraulic universal testing machine



The frequency converter is a power control equipment that uses frequency conversion technology and microelectronics technology to control AC motors by changing the frequency of the motor's working power supply.
Common failures of electronic universal testing machine



Electronic universal testing machine is a necessary equipment to control the quality of products.
Calibration method of electronic universal testing machine



The calibration operation of the electronic universal testing machine is still relatively unfamiliar to friends who use it for the first time.
Brief introduction of selective wave soldering defects and prevention



Selective wave soldering defects and their prevention.
Some precautions when using the testing machine



Testing machine, broadly speaking, is an instrument that verifies the quality or performance of a product or material according to the design requirements before it is put into use.
How to measure the tensile force of the testing machine



The tensile force is not an accurate value after being measured by the testing machine, and subsequent calculations are required to get the desired value.