How to adjust the indication error of the universal material testing machine?

How to adjust the indication error of the universal material testing machine?

According to the force value of the testing area of u200bu200bthe testing machine, clamp the standard tensile specimen of the corresponding force value on the testing machine, and let the testing machine stretch the standard tensile specimen at the speed specified in the GB/T228-2002 standard. When the standard tensile specimen is in tension, install an extensometer or stick a strain gauge on it, let the tensile testing machine continue to stretch the standard tensile specimen, and the extensometer or strain gauge will extend the extension of the standard tensile specimen Display, convert the elongation into a tensile value, and compare it with the same force point on the dial of the tensile testing machine as the standard tensile specimen, and determine the technical status and accuracy of the testing machine based on the difference of the comparison value. This method uses Hooke's law to convert the elongation of the standard tensile specimen into a force value and compare it with the dial force value of the testing machine to determine the accuracy of the testing machine. This method greatly simplifies the verification operation process, and brings great convenience and standardization to the daily verification of the original tensile state of the universal material testing machine. The verification method of the universal material testing machine is characterized in that, first, according to the force value of the tensile testing machine in the tested interval, select the standard tensile specimen, and the force value of the standard tensile specimen is 60% to 90% of the full-scale force value of the interval. To choose between, clamp the standard tensile specimen on the tensile testing machine, and let the tensile testing machine stretch the standard tensile specimen at the speed specified in the GB/T228-2002 standard, and immediately when the pointer of the tensile testing machine swings slightly Stop stretching, that is, the standard tensile test specimen is in a tensile state. At this time, install an extensometer or paste a strain gauge on the standard tensile test specimen, and let the tensile testing machine continue to test the standard tensile force at the speed specified in the GB/T228-2002 standard The sample is stretched, and the extensometer or strain gage displays the elongation of the standard tensile specimen. According to Hooke’s law, the elongation is converted to the tensile value, which is the same as the standard tensile specimen on the dial of the tensile testing machine. The force value points are compared, and the technical status and accuracy of the testing machine are determined according to the difference of the comparison value.

Previous post: Basic operation steps of steel bar bending test machine

Next article: YAW-2000D Automatic European Standard Pressure Testing Machine

GET IN TOUCH WITH Us
recommended articles
200 FAQs WHAT' S NEW APPLICATION
How to keep the hydraulic universal testing machine clean



Hydraulic universal testing machines have very high accuracy requirements.
Connection of hydraulic system of tensile testing machine



The hydraulic system is the power drive mechanism of the tensile testing machine.
Application of electronic universal testing machine in automobile industry



The specific application of the electronic universal testing machine in the automobile manufacturing process: The electronic universal testing machine needs to be used for automobile parts.
Wave soldering workflow



Wave soldering refers to the molten solder (lead-tin alloy), sprayed by electric pump or electromagnetic pump into the solder wave required by the design, can also be formed by injecting nitrogen into the solder pool, so that it is pre-loaded The printed board of the component realizes the soft soldering of the mechanical and electrical connection between the solder end or the pin of the component and the pad of the printed board through the solder wave.
Protection of frequency converter of hydraulic universal testing machine



The frequency converter is a power control equipment that uses frequency conversion technology and microelectronics technology to control AC motors by changing the frequency of the motor's working power supply.
Common failures of electronic universal testing machine



Electronic universal testing machine is a necessary equipment to control the quality of products.
Calibration method of electronic universal testing machine



The calibration operation of the electronic universal testing machine is still relatively unfamiliar to friends who use it for the first time.
Brief introduction of selective wave soldering defects and prevention



Selective wave soldering defects and their prevention.
Some precautions when using the testing machine



Testing machine, broadly speaking, is an instrument that verifies the quality or performance of a product or material according to the design requirements before it is put into use.
How to measure the tensile force of the testing machine



The tensile force is not an accurate value after being measured by the testing machine, and subsequent calculations are required to get the desired value.