The hydraulic universal testing machine needs to be adjusted to zero in order to get accurate test results, then the test method is as follows:

Test method:

1. Turn on the test equipment, computer, and control software;

2. For the hydraulic universal testing machine, select the appropriate range according to the sample, adjust the oil delivery valve to raise the cylinder piston, and repeat it several times. When the piston is rising and not under pressure, observe the computer's test at this time Whether the force value is zero, if it is not zero, click the hardware adjustment button to adjust the zero point;

3. When the zero point is too large, adjust the zero point first, and then reset the software to zero in each gear;

4. When the cylinder is not raised, the test force shows a negative value, which is a normal phenomenon, please do not adjust the zero point;

5. The adjustment of the zero point should be carried out after the extensometer is clamped on the sample and the test piston is in a static state;

6. Under normal circumstances, the speed regulator has adjusted the zero point of the sensor, and each time it is started, the system will automatically calibrate the start zero point, without the need for the user to adjust it;

7. The user can use the hardware zero adjustment button to adjust the hardware zero point, and the system will automatically record the new zero point adjustment value;

8. The zero point is not adjusted for non-step measurement.

Matters needing attention:

1. Please close the oil delivery valve in time. The oil delivery valve should be closed in time after shutting down before starting the machine. Loading, unloading and oil return must be carried out slowly to prevent shock;

2. After the sample of the hydraulic universal testing machine is tightened, the position of the clamp cannot be adjusted;

3. During use, the load of attention value and the movement of the beam should not exceed the maximum range;

4. After starting the machine, if there is any abnormality, you can press the emergency stop switch to turn off the testing machine.

The above is how the hydraulic universal testing machine zero adjustment and precautions shared by the editor, I hope it can help everyone!

Previous: WAW-2000E material testing machine

Next: Material testing machine WAW-2000E

GET IN TOUCH WITH Us
recommended articles
200 FAQs WHAT' S NEW APPLICATION
How to keep the hydraulic universal testing machine clean



Hydraulic universal testing machines have very high accuracy requirements.
Connection of hydraulic system of tensile testing machine



The hydraulic system is the power drive mechanism of the tensile testing machine.
Application of electronic universal testing machine in automobile industry



The specific application of the electronic universal testing machine in the automobile manufacturing process: The electronic universal testing machine needs to be used for automobile parts.
Wave soldering workflow



Wave soldering refers to the molten solder (lead-tin alloy), sprayed by electric pump or electromagnetic pump into the solder wave required by the design, can also be formed by injecting nitrogen into the solder pool, so that it is pre-loaded The printed board of the component realizes the soft soldering of the mechanical and electrical connection between the solder end or the pin of the component and the pad of the printed board through the solder wave.
Protection of frequency converter of hydraulic universal testing machine



The frequency converter is a power control equipment that uses frequency conversion technology and microelectronics technology to control AC motors by changing the frequency of the motor's working power supply.
Common failures of electronic universal testing machine



Electronic universal testing machine is a necessary equipment to control the quality of products.
Calibration method of electronic universal testing machine



The calibration operation of the electronic universal testing machine is still relatively unfamiliar to friends who use it for the first time.
Brief introduction of selective wave soldering defects and prevention



Selective wave soldering defects and their prevention.
Some precautions when using the testing machine



Testing machine, broadly speaking, is an instrument that verifies the quality or performance of a product or material according to the design requirements before it is put into use.
How to measure the tensile force of the testing machine



The tensile force is not an accurate value after being measured by the testing machine, and subsequent calculations are required to get the desired value.
no data

  Tel: 0086-0769-2318 4144

  Mobile: 0086-137 2828 8444

no data
CONTACT US

Copyright © 2025 Sinowon | All Rights Reserved.

Customer service
detect