loading

A professional manufacturer of measuring & testing equipment.

How to solve the astigmatism problem of the image measuring instrument?

How to solve the astigmatism problem of the image measuring instrument? The birth of the measuring instrument saves a lot of manpower and time. Therefore, it can avoid monotonous operation and heavy work, such as tired visual alignment, frequent point selection, repeated positioning and function switching, etc., so that work efficiency can be increased by hundreds of times. When using a fully automatic image measuring instrument , Pay attention to the maintenance of surface parts: When loading and unloading workpieces, the measuring platform should pay special attention to the glass platform. Sometimes a layer of water vapor and oil mist is formed on the measuring platform. Clean the dirt immediately and cover the shell when not in use. If the case is contaminated, please use a soft cloth to wipe the hard cloth, which may scratch the body. Although the pollution of the fuselage will not directly affect the measurement accuracy of the measuring instrument, the pollution may spread to the linear slide or the platform, which will affect the measurement accuracy of other parts. The problem of imaging astigmatism has always been one of the factors affecting the measurement accuracy of image measuring instruments. Many manufacturers and Ru0026D teams that manufacture image measuring instruments have been looking for ways to solve this problem, but there are too many factors that constitute these problems. We can only ensure the accuracy of image measuring instruments after checking and improving step by step. How to deal with it? In actual operation, after turning on and turning off the power, if the image is not concentrated on the large screen and the resolution is low, we call it the astigmatism problem of the image measuring instrument. At this point, no matter how you update the objective lens or change the measurement angle, the same screen will be displayed on the big screen. At the beginning of this situation, many people did not understand it and believed that it was caused by the dust on the lens. As a result, rubbing with their hands, the effect was counterproductive and the picture became more unclear. After determining the astigmatism of the image, it must be turned off Power is used to disassemble the body of the image measuring instrument, and then replace the lamp and install it on the lamp holder. This may be caused by the non-condensation of the light source. After replacement, turn on the power to check whether the problem has been solved. If the problem is still the same, you need to find other reasons to solve the problem. You can also check whether the glass mirror under the lamp holder is unevenly distributed. The non-uniformity is the cause of the astigmatism of the image measuring instrument, and it only needs to be replaced with a new glass mirror.

GET IN TOUCH WITH Us
recommended articles
200 FAQs WHAT' S NEW APPLICATION
How to keep the hydraulic universal testing machine clean



Hydraulic universal testing machines have very high accuracy requirements.
Connection of hydraulic system of tensile testing machine



The hydraulic system is the power drive mechanism of the tensile testing machine.
Application of electronic universal testing machine in automobile industry



The specific application of the electronic universal testing machine in the automobile manufacturing process: The electronic universal testing machine needs to be used for automobile parts.
Wave soldering workflow



Wave soldering refers to the molten solder (lead-tin alloy), sprayed by electric pump or electromagnetic pump into the solder wave required by the design, can also be formed by injecting nitrogen into the solder pool, so that it is pre-loaded The printed board of the component realizes the soft soldering of the mechanical and electrical connection between the solder end or the pin of the component and the pad of the printed board through the solder wave.
Protection of frequency converter of hydraulic universal testing machine



The frequency converter is a power control equipment that uses frequency conversion technology and microelectronics technology to control AC motors by changing the frequency of the motor's working power supply.
Common failures of electronic universal testing machine



Electronic universal testing machine is a necessary equipment to control the quality of products.
Calibration method of electronic universal testing machine



The calibration operation of the electronic universal testing machine is still relatively unfamiliar to friends who use it for the first time.
Brief introduction of selective wave soldering defects and prevention



Selective wave soldering defects and their prevention.
Some precautions when using the testing machine



Testing machine, broadly speaking, is an instrument that verifies the quality or performance of a product or material according to the design requirements before it is put into use.
How to measure the tensile force of the testing machine



The tensile force is not an accurate value after being measured by the testing machine, and subsequent calculations are required to get the desired value.
no data

  Tel: 0086-0769-2318 4144

  Mobile: 0086-137 2828 8444

no data
CONTACT US

Copyright © 2025 Sinowon | All Rights Reserved.

Customer service
detect