loading

A professional manufacturer of measuring & testing equipment.

What factors affect the static error of the coordinate measuring machine?

What factors affect the static error of the coordinate measuring machine? Published: 2019-10-23 Source: http://www.microaccuracy.com/ Although the coordinate measuring machine is a high-precision measuring device, it is easy to Cause various measurement errors, what factors affect the static error of the coordinate measuring machine? The measurement of industrial production design has high measurement accuracy requirements for the coordinate measuring machine. Any error should be avoided as much as possible. The static error of the coordinate measuring machine is mainly caused by the following aspects: 1. Due to structural parts (such as The geometric errors caused by the limited accuracy of the guide rail and measuring system are determined by the manufacturing accuracy of these structural parts and the adjustment accuracy during installation and maintenance. 2. The errors related to the finite stiffness of the mechanical parts of the coordinate measuring machine are mainly caused by the weight of the moving parts. These errors are determined by the stiffness, weight and their configuration of the structural parts. 3. Thermal errors, such as the expansion and bending of the guide rail caused by a single temperature change and temperature gradient. These errors are determined by the machine structure, material characteristics and temperature distribution of the coordinate measuring machine, and are affected by external heat sources (such as ambient temperature) and internal heat sources. (Such as driving device). 4. The error between the probe and the accessories mainly includes the change in the radius of the probe tip caused by the replacement of the probe, the extension of the extension rod, and the addition of other accessories, and the anisotropy error of the probe when it is touched in different directions and positions. Errors caused by the rotation of the indexing table, etc. The above are several factors that cause the static error of the coordinate measuring machine. As long as the measurement and use process is operated correctly and used in a suitable environment, regular maintenance of the coordinate measuring machine can effectively reduce the error to ensure the normality of the equipment. Circumstances, currently MiaoJi can provide a variety of high-precision coordinate measuring machines and one-button measuring instruments!

GET IN TOUCH WITH Us
recommended articles
200 FAQs WHAT' S NEW APPLICATION
How to keep the hydraulic universal testing machine clean



Hydraulic universal testing machines have very high accuracy requirements.
Connection of hydraulic system of tensile testing machine



The hydraulic system is the power drive mechanism of the tensile testing machine.
Application of electronic universal testing machine in automobile industry



The specific application of the electronic universal testing machine in the automobile manufacturing process: The electronic universal testing machine needs to be used for automobile parts.
Wave soldering workflow



Wave soldering refers to the molten solder (lead-tin alloy), sprayed by electric pump or electromagnetic pump into the solder wave required by the design, can also be formed by injecting nitrogen into the solder pool, so that it is pre-loaded The printed board of the component realizes the soft soldering of the mechanical and electrical connection between the solder end or the pin of the component and the pad of the printed board through the solder wave.
Protection of frequency converter of hydraulic universal testing machine



The frequency converter is a power control equipment that uses frequency conversion technology and microelectronics technology to control AC motors by changing the frequency of the motor's working power supply.
Common failures of electronic universal testing machine



Electronic universal testing machine is a necessary equipment to control the quality of products.
Calibration method of electronic universal testing machine



The calibration operation of the electronic universal testing machine is still relatively unfamiliar to friends who use it for the first time.
Brief introduction of selective wave soldering defects and prevention



Selective wave soldering defects and their prevention.
Some precautions when using the testing machine



Testing machine, broadly speaking, is an instrument that verifies the quality or performance of a product or material according to the design requirements before it is put into use.
How to measure the tensile force of the testing machine



The tensile force is not an accurate value after being measured by the testing machine, and subsequent calculations are required to get the desired value.
no data

  Tel: 0086-0769-2318 4144

  Mobile: 0086-137 2828 8444

no data
CONTACT US

Copyright © 2025 Sinowon | All Rights Reserved.

Customer service
detect