1. When installing the main ruler, for example, when installing a grating above 1.5M, it cannot be installed at both ends like a bridge type, and it needs to be supported in the entire main ruler body. 2. After installing the base, it is better to use clamps to clamp the midpoint or several points of the main body of the ruler. 3. If the fixing clip cannot be installed, it is better to use glass glue to stick the main body of the grating ruler, so that the bottom ruler and the main ruler are firmly fixed. 4. Installation of the reading head of linear scale linear displacement sensor. When installing the reading head, first make sure that the bottom surface of the reading head meets the installation requirements, and then install the reading head. The installation method is similar to the main ruler. Later, adjust the reading head to ensure The parallelism between the reading head and the main scale of the grating is within 0.1mm, and the gap between the reading head and the main scale is controlled within 1-1.5mm. 5. The limit device of the linear scale linear displacement sensor. After all the linear displacement sensors are installed, the limit device must be installed on the machine tool rail to prevent the reading head from hitting the two ends of the main ruler. When the machine tool moves, the scale is damaged. In addition, when purchasing a linear displacement sensor, users should try to use a grating ruler that is about 100mm larger than the machine tool processing size to allow a certain margin. 6. Inspection of the linear displacement sensor of the grating ruler. After installing the linear displacement sensor of the grating, you can open the digital display meter, move the workbench, observe whether the count of the digital display meter is normal, select the reference position on the machine, and then move the working point back and forth to At the selected position, the reading of the digital display should be the same or return to zero. In addition, you can also use a dial indicator or a dial indicator to adjust the dial indicator and the digital display to zero at the same time or remember the initial data. After several round trips, return to the original position to observe whether the data on the digital display is consistent with the indicator of the dial indicator. Through the above work, the image measuring instrument has completed the installation of the linear displacement sensor of the grating ruler. However, for the general machine tool processing environment, there are more iron filings, cutting fluid and oil stains. Therefore, the sensor should be attached with a protective cover. The design of the protective cover is determined by expanding a certain amount of space according to the shape and cross-section of the sensor. The protective cover is usually sealed with rubber to make it waterproof and oil-resistant.

GET IN TOUCH WITH Us
recommended articles
200 FAQs WHAT' S NEW APPLICATION
How to keep the hydraulic universal testing machine clean



Hydraulic universal testing machines have very high accuracy requirements.
Connection of hydraulic system of tensile testing machine



The hydraulic system is the power drive mechanism of the tensile testing machine.
Application of electronic universal testing machine in automobile industry



The specific application of the electronic universal testing machine in the automobile manufacturing process: The electronic universal testing machine needs to be used for automobile parts.
Wave soldering workflow



Wave soldering refers to the molten solder (lead-tin alloy), sprayed by electric pump or electromagnetic pump into the solder wave required by the design, can also be formed by injecting nitrogen into the solder pool, so that it is pre-loaded The printed board of the component realizes the soft soldering of the mechanical and electrical connection between the solder end or the pin of the component and the pad of the printed board through the solder wave.
Protection of frequency converter of hydraulic universal testing machine



The frequency converter is a power control equipment that uses frequency conversion technology and microelectronics technology to control AC motors by changing the frequency of the motor's working power supply.
Common failures of electronic universal testing machine



Electronic universal testing machine is a necessary equipment to control the quality of products.
Calibration method of electronic universal testing machine



The calibration operation of the electronic universal testing machine is still relatively unfamiliar to friends who use it for the first time.
Brief introduction of selective wave soldering defects and prevention



Selective wave soldering defects and their prevention.
Some precautions when using the testing machine



Testing machine, broadly speaking, is an instrument that verifies the quality or performance of a product or material according to the design requirements before it is put into use.
How to measure the tensile force of the testing machine



The tensile force is not an accurate value after being measured by the testing machine, and subsequent calculations are required to get the desired value.